Skip to main content

Radiation Safety Manual

Introduction
The objectives of the Arkansas State University Radiation Safety Program are to assist in
fulfilling the University's commitment to provide a safe and healthy environment for
employment and learning and to establish and promote safe practices at all times. Protection of
employees, students, the public, and university property and operations are paramount and every
attempt will be made to ensure that our facilities are as free as possible from recognized radiation
hazards.
The Arkansas Department of Health has issued a Specific Broad Scope License to Arkansas
State University. This license authorizes and tightly regulates the responsible use of
radionuclides on our campus.
The purpose of Arkansas State University's Radiation Safety Manual is to assist faculty, staff,
and students in complying with the regulations of the Arkansas Department of Health and the ASTATE Radiation Safety Committee. This manual is not intended to be an exhaustive or fully
comprehensive reference, but rather a guide to enable qualified personnel safe and efficient use
of radionuclides and ancillary staff protection from undesirable exposure to the effects of
radionuclide use. Further information associated with the use of radioactive materials on this
campus can be obtained by contacting the A-STATE Radiation Safety Officer.
Radiation Event Medical Management at the U.S. Department of Health & Human Services
http://remm.nlm.gov/
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 2
FOR
Emergency Assistance


In case of an emergency or accident situation:
Notify:
Radiation Safety Officer at 972-3644
or
Environmental Health & Safety at 972-2862


Nights, Weekends or Holidays:
Notify
University Police
972-2093
AND
Radiation Safety Officer
864-710-2933

For routine information contact the Radiation Safety Officer
at mdooley@astate.edu.

Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 3
Contents
Introduction ................................................................................................................................................................... 1
Chapter 1 Radiation Safety Committee ......................................................................................................................... 7
1.1 Purpose ................................................................................................................................................................ 7
1.2 Organization ........................................................................................................................................................ 7
1.3 Responsibilities .................................................................................................................................................... 7
Chapter 2 Radiation Safety Officer Duties and Responsibilities ..................................................................................... 8
Chapter 3- Chair of Department of Chemistry and Physics Duties and Responsibilities ................................................ 9
Chapter 4- Licensing and Registration Regulations ....................................................................................................... 9
4.1 Federal Regulations ............................................................................................................................................. 9
4.2 State Regulations ................................................................................................................................................. 9
4.3 Arkansas State University Campus Regulations................................................................................................. 10
4.4 Posting of Notices .............................................................................................................................................. 10
Chapter 5- Approved Users and Their Responsibilities ................................................................................................ 11
5.1 Principal User ..................................................................................................................................................... 11
5.2 Authorized User ................................................................................................................................................. 11
5.3 Individual User ................................................................................................................................................... 12
5.4 Responsibilities of Users..................................................................................................................................... 12
Chapter 6- Procurement, Receipt and Inventory of Radioactive Materials ................................................................. 13
6.1 Purchases ........................................................................................................................................................... 13
6.2 Receipt of Radioactive Materials ....................................................................................................................... 13
6.3 Transfer of Possession........................................................................................................................................ 15
6.4 Shipping of Radioactive Materials ..................................................................................................................... 15
6.5 Security and Storage of Radioactive Materials .................................................................................................. 15
6.5.1 Security ....................................................................................................................................................... 15
6.5.2 Storage ........................................................................................................................................................ 16
6.6 Transport of Portable Gauges ............................................................................................................................ 16
Chapter 7- Rules for the Safe Handling for Radioactive Materials .............................................................................. 16
7.1 Classification of Areas ........................................................................................................................................ 16
7.2.1 Unrestricted Areas ...................................................................................................................................... 16
7.1.2 Controlled Area ........................................................................................................................................... 17
7.1.3 Restricted Areas .......................................................................................................................................... 17
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 4
7.2 Radiation Dose Limits ........................................................................................................................................ 18
7.2.1 ALARA ......................................................................................................................................................... 18
7.2.2 Occupational Dose Limits ............................................................................................................................ 18
7.2.3 Minors Working with Radioactive Materials .............................................................................................. 19
7.2.4 Exposure Limits for the General Public ....................................................................................................... 19
7.2.5 Exposure Limits to an Embryo/Fetus .......................................................................................................... 19
7.3 Personnel Monitoring ........................................................................................................................................ 19
7.3.1 Dosimeters .................................................................................................................................................. 20
7.3.2 Bioassays .................................................................................................................................................... 20
7.4 Posting of Laboratories and Areas ..................................................................................................................... 21
7.5 Posting of Equipment ..................................................................................................................................... 22
7.6 Vacating Laboratory Spaces .............................................................................................................................. 22
Chapter 8 Surveys ........................................................................................................................................................ 22
8.1 Operating Procedures to Be Utilized by RSO ...................................................................................................... 22
8.2 User Guidelines for Conducting Surveys ............................................................................................................ 23
8.3 Contamination Levels......................................................................................................................................... 23
8.4 Leak Tests........................................................................................................................................................... 24
8.4 Survey Instruments and Calibration ................................................................................................................... 24
Chapter 9 Radioactive Waste ...................................................................................................................................... 25
9.1 Decay in Storage ................................................................................................................................................ 25
9.2 Disposal of Liquid Waste .................................................................................................................................... 25
9.3 Disposal of Solid Waste ...................................................................................................................................... 25
9.4 Animal Waste..................................................................................................................................................... 26
9.5 Records of Disposal ............................................................................................................................................ 26
Chapter 10 Emergency Procedures .............................................................................................................................. 26
10.1 Accident Procedures ........................................................................................................................................ 26
Chapter 11 Administrative Procedures ........................................................................................................................ 27
11.1 Violation Procedures ........................................................................................................................................ 27
11.2 Recordkeeping ................................................................................................................................................. 28
Appendix I Radiation Safety Committee Membership ................................................................................................. 28
Appendix II Acceptable Training and Experience Requirements for Users of Radiation Sources ................................. 28
II.1 Principal User ..................................................................................................................................................... 28
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 5
II.2 Authorized User ................................................................................................................................................. 29
II.3 Individual User ................................................................................................................................................... 29
II.4 Ancillary Personnel............................................................................................................................................. 29
Appendix III Inventory and Disposal Log for Radioactive Material .............................................................................. 30
Appendix IV Request for Approval to Use and Acquire Radioactive Material ............................................................. 31
Appendix V Logbook for Radioactive Material ............................................................................................................ 33
Appendix VI ADH Form Y .............................................................................................................................................. 34
Appendix VII Notice to Employees ............................................................................................................................... 35
Appendix VIII Materials Licensed for Use at Arkansas State University ...................................................................... 36
Appendix IX Guidelines for Bioassays .......................................................................................................................... 36
IX.1 Conditions under Which Bioassays May Be Necessary for the Use of I-125 and I-131 ..................................... 36
IX.2 Additional Information for Use of Tritium (H-3) ............................................................................................... 38
IX.2.1 Special Surveys ........................................................................................................................................... 38
IX.2.2 Handling of Contaminated Material .......................................................................................................... 39
IX.2.3 Bioassay Methods ...................................................................................................................................... 39
IX.2.4 Bioassay Frequency Guidelines .................................................................................................................. 40
IX.2.5 Bioassay Action Level and Corresponding Action Guidelines ..................................................................... 41
Appendix X Operating, Transport, Security and Emergency Guidelines for Portable Gauges ..................................... 42
X.1 Operating Procedures ........................................................................................................................................ 42
X.1.1 Preparation for Work .................................................................................................................................. 42
X.1.2 Using the Gauge ......................................................................................................................................... 42
X.1.3 Completing the Work .................................................................................................................................. 43
X.1.4 Maintaining the Gauge ............................................................................................................................... 43
X.2 Transportation of Portable Gauges ................................................................................................................... 43
X.2.1 Marking ...................................................................................................................................................... 44
X.2.2 Labeling ...................................................................................................................................................... 44
X.2.3 Shipping Papers .......................................................................................................................................... 44
X.2.4 Inspection.................................................................................................................................................... 45
X.2.5 Blocking and Bracing .................................................................................................................................. 45
X.2.5 Expected Instruments/Articles .................................................................................................................... 45
X.3 Security of Portable Gauges ............................................................................................................................... 46
X.3.1 Storage and Control of Licensed Radioactive Materials ............................................................................. 46
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 6
X.3.2 Security Requirements ................................................................................................................................ 46
X.3.3 Securing a Portable Gauge at a Licensed Facility ....................................................................................... 46
X.3.4 Securing the Portable Gauge in a Vehicle ................................................................................................... 47
X.3.5 Securing a Portable Gauge at a Temporary Job Site or at Locations other than a Licensed Facility .......... 48
X.3.6 Controlling and Maintaining Constant Surveillance of a Portable Gauge .................................................. 48
X.4 Emergency Procedures for Portable Gauges ..................................................................................................... 49
X.4.1 Individual at the Scene ................................................................................................................................ 49
X.4.2 RSO and License Management ................................................................................................................... 49

Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 7

Chapter 1 Radiation Safety Committee
1.1 Purpose
The Arkansas Department of Health, Division of Radiation Control and Emergency Management
regulations require the establishment of a Radiation Safety Committee (RSC). The purpose of the RSC is
to promote the best practice in safe handling and use of radiation sources. The RSC is also established to
assure compliance with State regulations and the conditions set forth by the license. Any individual or
action, which jeopardizes the license, endangers the permission of all researchers to utilize radioactive
materials at Arkansas State University.
1.2 Organization
The Radiation Safety Committee, which meets at least annually and as necessary to conduct the
business of the radiation safety program, is comprised of the Radiation Safety Officer, Committee Chair
(an appropriate representative appointed by the Office of Research and Academic Affairs), one (1)
licensed user, one (1) physicist with knowledge of radiation physics and two (2) faculty members, one of
which must be from outside ABI, Agriculture, and the College of Science and Mathematics, trained and
experienced in the safe use of radioactive materials.
1.3 Responsibilities
This Committee is responsible for establishing procedures and policies for the authorized procurement,
protection, use, and disposal of radioactive materials and for the safety and protection of all personnel,
students and visitors, on the Arkansas State University Campus. The Committee shall:
1. Provide technical and administrative guidance and aid in the interpretation of various
regulations governing the use of radioactive materials.
2. Review and act upon all new, renewal, and amended applications for possession and use of
radioactive materials.
3. Determine the adequacy of training and experience of persons requesting permission to use or
supervise the use of radioactive materials.
4. Determine the suitability of space, facilities, or equipment designated for use or storage of
radioactive materials.
5. Receive and review periodic reports from the RSO on monitoring, contamination, and personnel
exposure.
6. Meet, at the call of the chair of the Radiation Safety Committee or designated representative, to
review alleged infractions of safety rules and regulations, incidents, and emergencies concerning
any radiation program or project.
7. Provide recommendations to the RSO for items 3-6 above.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 8
Chapter 2 Radiation Safety Officer Duties and Responsibilities
Radiation Safety Officer derives authority from the Division of Finance and Administration with support
from the Office of Research and Academic Affairs. The RSO’s duties and responsibilities include ensuring
radiological safety and compliance with Arkansas Department of Health Division of Radiation Control
and Emergency Management and Department Of Transportation regulations and the conditions of the
University license. The RSO’s duties and responsibilities include the following:
1. Ensure that the radioactive material possessed by Arkansas State University is limited to the
types and quantities of material listed on the license.
2. Oversee all activities involving radioactive material, including monitoring and surveys of all areas
in which radioactive material is used and stored.
3. Provide necessary information on all aspects of radiation protection to personnel at all levels of
responsibility.
4. Oversee proper delivery, receipt, and radiation surveys of all shipments of radioactive material
arriving at the University, as well as proper packaging and labeling of all radioactive material
being shipped from the University.
5. Maintain an active inventory of all radioisotopes housed at Arkansas State University and
records of their disposal.
6. Distribute and process personnel radiation monitoring equipment, determine the need for and
evaluate bioassays, monitor personnel radiation exposure and bioassay records for trends and
high exposures, notify individuals and their supervisors of radiation exposures approaching the
limits, and recommend appropriate remedial action.
7. Coordinate or conduct training programs and otherwise instruct personnel in the proper
procedures for handling radioactive material prior to use, at periodic intervals (annual refresher
training), and as required by changes in procedures, equipment, regulations, etc. Ensure that all
ancillary employees and emergency personnel whose assigned duties may involve exposure to
radioactive materials in the course of their employment are trained in Radiation Safety.
8. Supervise and coordinate the radioactive waste disposal program, including effluent monitoring
and recordkeeping on waste storage and disposal records.
9. Oversee and manage the storage of radioactive material not in current use, including waste.
10. Perform or arrange for leak tests on all sealed sources and for calibration of radiation survey
instruments.
11. Immediately terminate any unsafe condition or activity that is found to be a threat to public
health and safety or property.
12. Maintain other records not specifically designated above, including records of receipts,
transfers, and surveys as required by Arkansas Department of Health Rules and Regulations.
13. Attend periodic meetings of the Radiation Safety Committee and provide reports to the
Committee and Vice Chancellor for Research and Academic Affairs.
14. Ensure that the results of audits, identification of deficiencies, and recommendations for change
are documented (and maintained for at least 3 years) and provided to the Radiation Safety
Committee and the Vice Chancellor for Research and Academic Affairs for review; ensure that
prompt action is taken to correct deficiencies.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 9
15. Ensure that the audit results and corrective actions are made available to all personnel who use
licensed material.
16. Ensure that all incidents, accidents, and personnel exposure to radiation as defined by the ASBH
Rules and Regulations are investigated and reported to the Arkansas Department of Health and
other appropriate authorities, if required, within the required time limits.
17. Maintain understanding of and up-to-date copies of regulations, the license and revised license
procedures, and ensure that the license is amended whenever there are changes in licensed
activities or responsible individuals.
Chapter 3- Chair of Department of Chemistry and Physics Duties and Responsibilities
The Chair of the Department of Chemistry and Physics functions under the Dean of the College of
Sciences and Mathematics. In relation to the Radiation Safety Program, the Chair of the Department of
Chemistry and Physics is responsible for performing periodic audits of the radiation safety program to
ensure that the RSO and all associated users are complying with all applicable Arkansas Department of
Health regulations and the terms and conditions of the license (i.e., leak tests, inventories, use limited to
trained approved users, etc.). Internal audits of the Radiation Safety program at Arkansas State
University are performed two times per year and a copy of the results of the audit are sent to the
Associate Vice Chancellor for Research.
Chapter 4- Licensing and Registration Regulations
4.1 Federal Regulations
There are several areas in which the Federal Government retains regulatory powers in agreement states
such as Arkansas.
1. The receipt, possession, use or transfer of by-product, source or special nuclear materials in
quantities sufficient to form a critical mass.
2. The construction and operation of any production or utilization facility.
3. The export from or import into the United States of by-product, sources, special nuclear
material, or electronic devices.
4. Any agency of the Federal Government.
In all other cases the Arkansas Department of Health, Division of Radiation Control and Emergency
Management is given the power to license and regulate the receipt, possession, use and transfer of
sources of ionizing radiation.
4.2 State Regulations
Because Arkansas is an agreement state, the Division of Radiation Control and Emergency Management
of the Arkansas Health Department is empowered to license or register radiation sources and to enforce
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 10
the regulations governing the activities of a licensee or registrant. Arkansas State University has been
issued a specific broad scope license.
Within the conditions imposed by the Arkansas Department of Health through the Rules and
Regulations, the licensee (A-STATE) is allowed to state what procedures it will follow in the safe use of
radioactive materials. Our radioactive materials license therefore contains both state requirements and
self-imposed operating procedures that have been approved by the state. When A-STATE is inspected,
we are examined for compliance with both the Rules and the conditions of our license.
Copies of the Rules and Regulations for Control of Sources of Ionizing Radiation are at Environmental
Health & Safety (117 Administration Building. A copy of these regulations may also be obtained by
writing to the Division of Radiation Control and Emergency Management, Arkansas Department of
Health, 4815 West Markham Street, Slot 30, Little Rock, Arkansas 72205-3867 or by visiting:
http://www.healthy.arkansas.gov/images/uploads/rules/October_1_2017_regulations_FINAL.pdf
Copies of the current radioactive materials license with all the amendments approved can be found in
the Environmental Health & Safety Office.
4.3 Arkansas State University Campus Regulations
No person may use or transfer radioactive materials into or on the campus of Arkansas State University
without prior approval by the Radiation Safety Committee.
All statements related to procurement, use and disposal of radioactive materials appearing in this
booklet will be considered as the regulations for Arkansas State University, as they reflect the Rules and
Regulations, the A-STATE license, and the policy decisions of the A-STATE Radiation Safety Committee.
This manual is not intended to be a comprehensive reference. If further information is needed, consult
the Arkansas Department of Health, Rules and Regulations for Control for Sources of Ionizing Radiation,
the A-STATE license, or the Radiation Safety Officer.
4.4 Posting of Notices
The Arkansas Department of Health (ADH) has adopted regulations with standards to protect you from
hazards associated with radioactive materials, which are licensed by the ADH. The ADH requires that
Arkansas State University post in a conspicuous place for all employees working in any portion of a
restricted area a copy of RH-2824 "Notice to Employees" "Standards for Protection Against Radiation".
See Appendix VII.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 11
Chapter 5- Approved Users and Their Responsibilities
5.1 Principal User
Principal Users are those persons who are permitted by the Radiation Safety Committee to purchase,
store and use radioactive materials under the Arkansas State University license (See Appendix II for
Training and Experience Requirements). The Principal Users are responsible for the safe use of radiation
sources by individuals under their control. The principal user is responsible for:
1. Compliance with the A-STATE rules and regulations for radiation safety and the State "Rules and
Regulations for the Control of Sources of Ionizing Radiation".
http://www.healthy.arkansas.gov/images/uploads/rules/October_1_2017_regulations_FINAL.p
df
2. Obtaining approval of the Radiation Safety Committee prior to obtaining radioactive materials
or carrying out a research protocol involving radioactive materials. A "Request to Use/Acquire
Radioactive Materials" (Appendix IV) must be completed by the Principal user and must be
approved by the RSC prior to beginning research.
3. Ensuring that all authorized users have successfully completed Arkansas Department of Health
training disk or another approved training program. All principal users must have completed the
course or show documentation of equivalent knowledge or experience.
4. Developing protocols for the research/experiment, to ensure that appropriate safety
precautions are taken.
5. Notifying the RSO prior to any personnel changes, including addition or termination of
employees/students, or changes in operational procedures, new techniques, or changes of areas
where radioactive materials may be used or stored.
6. Directing of personnel under their control to comply with all recommendations to wear pocket
dosimeters and finger badges, to survey their hands and clothing, to submit to bioassay, etc.
which are designed to control and to reduce their total exposure.
7. Maintenance of required records of receipt, use, storage, and disposal of radioisotopes.
8. Segregation, containment, labeling, and proper disposal of all radioactive waste in accordance
with guidelines.
9. Promptly notifying the Radiation Safety Officer of any accidents or incidents.
10. Ensuring that the personnel under their control discharge their individual responsibilities as
listed in Section 5.4.
NOTE: Cleanup of contaminated equipment or areas is the responsibility of the principal user and the
persons creating the contamination. It may not be assigned or delegated to staff outside the laboratory,
such as custodial or maintenance workers.
5.2 Authorized User
An authorized user is a person who has been added to the Principal User’s Authorization and has
completed the appropriate training as outlined in Appendix II. The authorized user is responsible to the
Principal User for all actions listed below for radioactive material. This user may work with isotopes or
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 12
equipment without immediate supervision, and may assume limited responsibilities as defined by the
Principal User.
5.3 Individual User
An individual user is a person who works with radioactive material and has completed the required
training as designated in Appendix II. The user must be listed on the Principal Users authorization list as
an individual user, and is responsible to the Principal User for all actions listed below. The individual
must work under direct supervision of the Principal User or an Authorized User designated by the
Principal User.
5.4 Responsibilities of Users
One of the basic tenets of safety is that all individuals must take responsibility for their own safety, and
ensure that any actions taken do not constitute a hazard to others or to the environment. Each person
at Arkansas State University who has any contact with sources of radioactive materials has the following
responsibilities:
1. Keep exposure to radiation As Low As Reasonably Achievable (ALARA).
2. Expose liquid or other sources that will disperse in the atmosphere under fume hoods.
3. Wear the recommended radiation monitoring devices for personnel, such as pocket dosimeters
and finger badges.
4. Use all recommended protective measures such as protective clothing, remote-handling tools.
Mouth pipetting is prohibited.
5. DO NOT smoke, eat, drink, chew gum or tobacco, or apply cosmetics or contact lenses in an area
where radioactive materials are used or stored. DO NOT store or prepare food or drink in any
area that has been used for radioactive materials, e.g., refrigerators, cabinets, glassware. If food
or empty food packaging is found in the normal trash, this is interpreted as "evidence of
consumption" by regulators.
6. Maintain good housekeeping and clean working habits. Work surfaces must be covered with a
plastic backed absorbent paper. Where practical, an impervious tray or pan should be used
under the paper in order to ensure containment of spills. Working areas must be clearly
delimited.
7. Survey work areas at least weekly when less than 200 uCi are used; otherwise survey daily at the
end of each laboratory or work period.
8. Label radiation equipment and segregate radioactive waste and equipment to avoid cross
contamination.
9. Report immediately to the Principal User and RSO the details of a spill or other accidents
involving radioactivity.
10. Maintain a log of all meter and wipe surveys conducted by the user. (See Appendix V for
Logbook Guidelines).
11. Carry out decontamination procedures when necessary and take the necessary steps to prevent
the spread of contamination to other areas.
12. Clean hands when leaving the laboratory.
When using radioisotopes other than low energy beta emitters, the following extra precautions are
required:
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 13
13. Place all sources behind suitable shielding.
14. Survey hands, feet, clothing and personal materials at the end of each laboratory or work
period.
15. Monitor radiation with a survey meter when radioisotopes are being used.
16. Annual retraining
Chapter 6- Procurement, Receipt and Inventory of Radioactive Materials
6.1 Purchases
The Principal User must submit to the Radiation Safety Officer a "Request for Acquisition of Radioactive
Material form (Appendix IV) detailing the description of the radioactive material, sources or equipment
to be ordered, intended use and planned disposal. The description shall indicate the radioisotope, its
chemical and physical form, and the total activity in Becquerels, millicuries or microcuries. Before
committee discussions, the RSO checks to insure that all requested radioisotopes are authorized by ASTATE’s license and do not exceed the authorized possession limits.
The Radiation Safety Committee will then check each request for proper use of radioisotopes. The
deliberations will include:
1. Whether the training and experience of the proposed user(s) are adequate for the proposed
purposes and for possible emergency procedures.
2. Ensure the available facilities and equipment (or those to be obtained) do not compromise
safety and are adequate for the stated needs.
3. Review proposed use to ensure all federal, state, and local safety requirements will be met.
4. Review the operating, handling, and emergency procedures to ensure they are adequate for this
material.
After approval by the RSC, ordering information is provided to the University purchasing agent, including
instructions to have the material sent directly to the Central Receiving, c/o Radiation Safety Officer,
Arkansas State University, 2713 Pawnee Dr. State University, Arkansas 72467. Arrangements must be
made for delivery to occur during normal working hours.
6.2 Receipt of Radioactive Materials
Within 3 hours of arrival of the radioisotope (this includes radioisotopes brought to campus personally
by a Principal User) the Radiation Safety Officer will be contacted immediately by Central Receiving to
handle the package, wearing gloves, check the package for contamination and enter the radioisotope
into the inventory (in accordance with RH-1307). Shipping and receiving personnel are instructed to
immediately contact the RSO if there is any obvious damage to the packaging. Only after checking for
contamination and confirming the lack thereof will the RSO notify the Principal User of satisfactory
receipt and availability of material.
Upon receipt of a sealed source, a survey of the packing material and surface of the instrument will be
performed in a secure area to verify integrity of contents. If damage and contamination has resulted
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 14
from shipment or receipt, the Arkansas Department of Health and the manufacturer will be immediately
notified, without delay.
Survey criteria for external surveys are as follows:
LABEL CRITERIA FOR RADIOACTIVE MATERIAL PACKAGES
DOSE RATE LIMITS
AT ANY POINT ON AT THREE FEET FROM
ACCESSIBLE SURFACE EXTERNAL SURFACE
LABEL OF PACKAGE OF PACKAGE
*RADIOACTIVE- WHITE I* 0.5 mR/hr 0.0 mR/hr
*RADIOACTIVE- YELLOW II* 50 mR/hr 1.0 mR/hr
*RADIOACTIVE- YELLOW III 200 mR/hr 10 mR/hr
The area designated for receipt and inspection of newly delivered radioisotopes is LSE 102E. Within
three hours of receipt, the package is surveyed, swipe tested, unpacked and checked for shipping
damage. Contents are verified to match with packing slip and box labeling. The integrity of the final
source container will be inspected to look for breakage of vials or seals, leakage or discoloration of
packing material. A Radioactive Receipt Form is completed and the material is logged in and stored until
delivery to the authorized user (attached). Records will be maintained for at least 3 years beyond the
usage of that radioisotope. The shipping box will be disposed of once all identifying labels are removed
or defaced. Packing material which is contaminated will be treated as radioactive waste. The carrier
and the Arkansas Department of Health, Radiation Safety Department, will be notified on the event that
surface contamination exceeds the limits of 10 CFR 71.87(1), or when external radiation levels exceed
the limits of 10 CFR 71.47.
The Assistant Radiation Safety Officer is on call to receive packages when the Radiation Safety Officer is
unavailable.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 15
6.3 Transfer of Possession
Outside Agencies - All radioactive material must enter and exit the campus through the Radiation Safety
Officer. Before material may be released to anyone not directly associated with Arkansas State
University, the RSO will be notified of the desired transfer. The RSO will ensure that all federal and state
regulations are followed, in accordance with RH-501 of the ADH Rules and Regulations. The following
information must be provided prior to the transfer taking place:
1. Name of institution receiving radioactive material and a written certification from that
institution identifying authorization to receive the type, form and quantity of radioactive
material to be transferred. The certification must also include the current license number,
expiration date and issuing agency name.
2. Name of Radiation Safety Officer at receiving institution.
3. Isotope, chemical compound, and amount of activity.
This is necessary for compliance with Arkansas State University license and to avoid potential legal
prosecution. A documented record of all such transactions will be maintained by the RSO in accordance
with RH-3200 of the ADH Rules and Regulations set forth by the Department of Transportation, 49 CFR
Parts 170 through 189. The Radiation Safety Officer will prepare the package for shipping.
Interdepartmental - Internal transfer of radioactive material will be approved by the RSO. These
transfers must be between committee-approved principal users. The recipient will have a current
authorization for the same radioactive material. Receipts of such transfers will be maintained by the
parties involved and by the RSO.
6.4 Shipping of Radioactive Materials
Radioactive materials may only be shipped by the Radiation Safety Officer (who maintains up to date
training for Department of Transportation Hazardous Materials Shipping). Shipping by any other
university personnel (aside from the transportation described in section 6.6) is prohibited.
6.5 Security and Storage of Radioactive Materials
6.5.1 Security
The Arkansas Department of Health rules and regulations require that security of radioactive materials
must be in place at all times. Violations of this regulation are frequently cited at institutions utilizing
radioactive materials, and place the license to use such materials in jeopardy. Section RH-1308, of the
state Rules and Regulations reads:
“The Licensee shall control and maintain constant surveillance of licensed material that is in a controlled
or unrestricted area and that is not in storage.”
This means that in all locations where radioactive materials are present the trained user must be in
constant attendance. Otherwise the lab must be locked or secured to prevent unauthorized removal or
access. If the laboratory is unoccupied access to the lab MUST BE LOCKED.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 16
6.5.2 Storage
Radioactive materials shall be stored in sealed containers in such a way as to prevent accidental spillage
or breakage, and to prevent release into the air. If the material requires shielding, it shall be stored in
shielded containers in order to prevent doses to personnel accessing the storage areas.
If the radioactive material has been stored in a freezer or ultra freezer, it is recommended that the
material be thawed, opened and handled in a certified fume hood or biological safety cabinet. Aerosols
from stored radioactive materials may cause contamination of adjacent areas and doses to personnel if
not handled in the proper way after storage. All radioactive materials, whether in storage, waste or use,
must be labeled with the radioactive warning symbol and the words "Caution, Radioactive Materials".
6.6 Transport of Portable Gauges
Appropriate regulations and labeling as required by the U.S. Department of Transportation will be
followed when radioactive material is transported between locations. Transportation of portable
gauges (e.g., CPN 503DR Hydroprobe) will be in compliance with Appendix M of the Portable Gauge
Licensing Guide (Appendix X). The Principal or Authorized user will be responsible for ensuring that the
gauges are properly labeled, packaged, secured and documented. Markings are to include the
following: shipping name, RQ, identification number, and package type. DOT warning labels must be
present on both sides of the carrying case as appropriate for the radiation levels at the surface and at 1
m. A bill of lading is required to be maintained within the travel vehicle for transport to assure
compliance of Appendix M. Included within the bill of lading is an emergency response telephone
number. Prior to each transport a visual inspection is to be made to ensure there is no damage. If
defects are identified the RSO must be notified, who will coordinate the repair or discontinuance of the
gauge. The portable gauge is to be physically secured at all times to prevent shifting during transport.
Any person that transports the portable gauge must complete Department of Transportation Hazardous
Materials Shipping training specific to the transport of the gauge and must keep the training current
according to DOT regulations. Courses that meet the university training requirements are contained in
the Hazardous Materials Shipping Program.
Chapter 7- Rules for the Safe Handling for Radioactive Materials
7.1 Classification of Areas
All rooms or areas in which licensed quantities of radioactive materials are used or stored must be
posted with a "Caution Radioactive Material" sign and a "Notice to Employees".
7.2.1 Unrestricted Areas
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 17
An unrestricted area is any area to which access is not controlled by the licensee or principal user for the
purposes of protection of individuals from exposure to radiation and radioactive materials. An area is
unrestricted and does not require control measures:
1. If an individual continually present in the area cannot receive more than 0.0002rem (0.02 mSv)
in any one hour or 0.05 rem (0.5 mSv) in a calendar year; and
2. If, when allowance is made for expected occupancy and time variations in dose-rate, no
individual is likely to receive more than 500 mrem (5 mSv) in a calendar year.
Radioisotopes may be transported through an unrestricted area, but may not be used in an unrestricted
area.
7.1.2 Controlled Area
A controlled area is outside of a restricted area, but inside the site boundary. A controlled area in which
radioisotopes are used and access is limited, but the potential exposure rates fall well below the limits
that define a Restricted Area.
7.1.3 Restricted Areas
All areas within the University in which dose levels do not conform to the standard for unrestricted
areas shall be restricted and under the control of the Radiation Safety Officer for radiation safety
purposes are restricted areas. The approved user responsible for work with radioisotopes in that area
shall be responsible for controlling access to the area. Both Federal and State regulations define
restricted areas containing radiation requiring special control measures as follows:
1. Radiation Area - An area accessible to individuals in which radiation levels could result in an
individual receiving a dose equivalent in excess of 0.005 rem (0.05 mSv) in any one hour at 30
centimeters from the radiation source or from any surface that the radiation penetrates. A sign
bearing the radiation symbol and the words "Caution Radiation Area - No Entrance to
Unauthorized Personnel" is to be posted at the entrance.
2. High Radiation Area - An area accessible to individuals in which radiation levels from radiation
sources external to the body could result in an individual receiving a dose equivalent in excess of
0.1 rem ( 1 mSv) in one (1) hour at thirty (30 centimeters from the radiation source or thirty (30)
centimeters from any surface that the radiation penetrates. A sign bearing the radiation symbol
and the works "Caution High Radiation Area - No Entrance to Unauthorized Personnel" is to be
posted at the entrance.
3. Very High Radiation Area - any area, accessible to individuals, in which radiation levels could
result in an individual receiving an absorbed dose in excess of 500 rads * (5 gray) in one hour at
one meter from the radiation source or from the surface that the radiation penetrates.
*NOTE - At Very High doses received at high dose rates, units of absorbed dose (e.g., rads and grays) are
appropriate, rather than units of dose equivalent (e.g., rems and sieverts).
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 18
Within the restricted area, strict surveillance should be maintained to assure that significant exposure
levels are not present, whether in the form of contamination, airborne levels of radiation or external
exposure levels.
7.2 Radiation Dose Limits
7.2.1 ALARA
ALARA is an acronym meaning As Low As Reasonably Achievable. It is a requirement in the law for all
facilities possessing radioactive materials licenses to have a formal ALARA program. The radiation
protection standards set forth in this manual are used to control radiation exposure to all personnel
occupationally exposed to radiation. It is the policy of Arkansas State University to keep this exposure as
low as reasonably achievable (ALARA).
7.2.2 Occupational Dose Limits
Occupational dose limits to individual adults shall be in accordance with RH-200 of the Arkansas
Department of Health, Rules and Regulations. No individual may receive in one calendar year, except
for planned special exposures, a total occupational exposure in excess of the following:
Total Effective Dose 5 rems (0.05
Sv), or
Sum of deep-dose
equivalent and committed
dose equivalent to any
individual organ or tissue
other than the lens of the
eye
50 rems (0.5
Sv)
Lens of the eye (lens dose) 15 rems
(0.15Sv) and
Skin & extremities Shallow dose
equiv. of 50
rems (0.50Sv)
DE – Dose Equivalent is the product of the absorbed dose in tissue, quality factor, and all other
necessary modifying factors at the location of interest. The units of dose equivalent are the rem and
sievert (Sv).
CDE – Committed Dose Equivalent (HT,50) is the dose equivalent to organs or tissues of reference (T) that
will be received from an intake of radioactive material by an individual during the 50-year period
following the intake.
EDE – Effective Dose Equivalent (HE)is the sum of the products of the dose equivalent to the organ or
tissue (HT) and the weighting factors (WT) applicable to each of the body organs or tissues that are
irradiated (HE = ∑ wTHT).
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 19
CEDE – Committed Effective Dose Equivalent (HE,50) is the sum of the products of the weighting factors
applicable to each of the body organs or tissues that are irradiated and the committed dose equivalent
to these organs or tissues (HE,50 = ∑ WTHT,50).
DDE – Deep Dose Equivalent (Hd), (which applies to external whole-body exposure) is the dose
equivalent at a tissue depth of 1 cm (1000 mg/cm2
).
TEDE – Total Effective Dose Equivalent is the sum of the deep-dose equivalent (for external exposures)
and the committed effective dose equivalent (for internal exposures).
SDE – Shallow-dose Equivalent (Hs), (which applies to the external exposure of the skin or an extremity)
is the dose equivalent at a tissue depth of 0.007 centimeter (7mg/cm2
), averaged over an area of one
(1) square centimeter.
LDE – Lens of Eye Dose Equivalent. Applies to the external exposure of the lens of the eye and is taken
as the dose equivalent at a tissue depth of 0.3 centimeter (300 mg/cm2
).
7.2.3 Minors Working with Radioactive Materials
The annual occupational dose limits to minors, (individuals under the age of 18) must be limited to ten
percent (10%) of the annual dose limits specified for adult workers. For these workers/students, safety
training must be completed prior to work with radioactive materials as with other occupational workers
and students.
7.2.4 Exposure Limits for the General Public
Any person who is not regularly employed or authorized in using radioactive materials must not receive
a radiation dose in excess of either:
 0.1 rem (1 mSv) in any one year.
 0.002 rem (0.02 mSv) in any one hour.
7.2.5 Exposure Limits to an Embryo/Fetus
Arkansas State University incorporates radiation dose guidelines, in accordance to RH-1207 of the ADH
Rules and Regulations, for ensuring safe radiation limits for the embryo/fetus of occupationally exposed
employees. Pregnant radiation workers who wish to declare their pregnancy should notify the Radiation
Safety Officer in writing as soon as possible after learning of their pregnancy.
The regulatory dose limit to the embryo/fetus of a declared pregnant woman is 0.5 rem (5 mSv) for the
entire pregnancy period.
The dose equivalent to the embryo/fetus is the sum of the deep-dose equivalent to the declared
pregnant woman and the dose equivalent to the embryo/fetus resulting from radionuclides in the
embryo/fetus and radionuclides in the declared pregnant woman.
7.3 Personnel Monitoring
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 20
Personnel monitoring of exposure to radiation and radioactive materials shall be performed to
demonstrate compliance with the occupational dose limits. As a minimum, individual monitoring devices
will be required where:
1. An individual receives or is likely to receive in one year from sources external to the body, a
dose in excess of ten (10) percent of the applicable limits (Section 7.2.2).
2. An individual enters a high or very high radiation area.
3. A minor is likely to receive, in one year, from sources external to the body, a dose in excess of
ten (10) percent of the applicable annual limit RH1206 or RH1207, Arkansas Rules and
Regulations; and
4. A declared pregnant woman is likely to receive during the entire pregnancy from radiation
sources external to the body, a deep dose equivalent in excess of 0.5 rem (5 mSv).
(All of the Occupational Doses in Section 7.2.2 continues to be applicable to the declared pregnant
worker as long as the embryo/fetus dose limit is not exceeded.)
5. Specific radioisotopes include the following: P-32 in aqueous form and moisture density gauges
(Cs-137 and Am-241).
6. Monitoring of these isotopes will continue as long as there is measurable activity. TLDs will be
exchanged quarterly through the manufacturer.
7.3.1 Dosimeters
The principal user is responsible for seeing that each person under his/her control is issued a radiation
dosimeter when his/her activities may result in exposures greater than the annual dose limits outlined in
Section 7.2.
Finger rings and chest thermoluminescent dosimeters (TLDs) will be worn by individuals working with
radioisotopes or during their entry of ABI 356 and LSE 102E (unless entry to the room is cleared by the
RSO in the absence of ongoing radiation work. Users working with gauges, which are sources of gamma
and neutron radiation, must wear chest and ring TLDs. TLDs must never be shared with another
individual and be used only for occupational (or class) exposure monitoring. The University will supply
TLDs obtained from an accredited dosimetry service approved by the Arkansas Department of Health.
TLDs will be exchanged and monitored on a quarterly basis.
7.3.2 Bioassays
The Radiation Safety Officer will request a bioassay if an individual’s dose, determined by area
contamination or pocket dosimeter, warrants a further medical check, or if a bio-contamination type
accident occurs. If the quantity of H-3 or other biohazardous radioisotopes used is large enough (more
than 0.1 mCi) to suggest a possible hazard, a bioassay procedure will be instituted (See Appendix
IX "Guidelines for Bioassays").
IF YOU SUSPECT THAT YOU HAVE RECEIVED A SIGNIFICANT EXPOSURE, CONTACT THE RADIATION
SAFETY OFFICER IMMEDIATELY.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 21
7.4 Posting of Laboratories and Areas
All lab areas that contain radioactive material will be indicated by the posting of the standard trefoil
warning sign at the entrance to the laboratory. Address and telephone numbers of the principal user
involved with the lab will be clearly indicated thereon. Signs are required by regulation to denote areas
or containers with levels of radiation or radioactivity specified in the following sections:
Radiation Areas: Each radiation area shall be conspicuously posted with a sign or sign bearing the
radiation symbol and the words "CAUTION RADIATION AREA" in areas accessible to personnel in which
the total effective dose received in any one hour exceeds 0.002 rem (0.02 mSv) and 0.05 rem (0.5 mSv)
in a year.
High Radiation Areas: Each high radiation area shall be posted with a sign or signs bearing the radiation
symbol and words "CAUTION HIGH RADIATION AREA". In addition, one or more of the following
features must be utilized at the entrance or access point to the high radiation area:
1. A control device that upon entry causes the level of radiation to be reduced below the level at
which an individual might receive a deep-dose equivalent of 0.1 rem (1mSv) in one (1) hour at
30 centimeters from the radiation source or from any surface that the radiation penetrates.
2. A control device that energizes a conspicuous visible or audible alarm signal so that the
individual entering the high radiation area and the supervisor of the activity are made aware of
the entry; or
3. Entryways that are locked, except during periods when access to the area is required, with
control over each individual entry.
Very High Radiation Areas: Each area in which there may exist radiation levels in excess of 500 rads (5
grays) in one (1) hour at one (1) meter from a radiation source or any surface through which the
radiation penetrates must be posted with a sign or signs bearing the radiation symbol and "GRAVE
DANGER, VERY HIGH RADIATION AREA". Each entrance or access point must be equipped with entry
control devices which function automatically to prevent any individual from inadvertently entering the
area when very high radiation levels exist.
Radioactive Materials: Each laboratory or area where radioactive materials are used or stored must be
posted at the entrance with a "CAUTION RADIOACTIVE MATERIALS" sign. Entry and area warning signs
are to be posted and removed only after notifying the RSO.
Refrigerators, freezers, and other "in lab" storage areas, and containers in which materials are stored or
transported must have a visible label with the radiation caution symbol and the words "Caution
Radioactive Materials". The label should also state the kind and approximate quantity (e.g. "< 250 Ci) of
radioactive material in the container.
AIRBORNE RADIOACTIVITY AREAS: The Radiation Safety Officer must give approval prior to any
research utilizing airborne radioactive materials. Any room, area or enclosure in which airborne
radioactive materials exist in concentration excess of the amounts specified in RH 2200, Appendix A,
Table 1, Column 1 of the ADH Rules and Regulations.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 22
7.5 Posting of Equipment
All vessels containing radioactive materials will be clearly marked with radiation warning tape and/or
labels stating:
1) Radioisotope
2) Chemical Form of the Radioisotope
3) Total Activity at date of purchase
4) Date of Purchase
All glassware used in experiments involving radioisotopes will be labeled with radiation warning tape,
with the particular radionuclide(s) inscribed thereon, until the vessel has been decontaminated and
checked for radiation.
7.6 Vacating Laboratory Spaces
The Radiation Safety Officer must be informed of all changes in authorized laboratory spaces. Upon
notification, the Radiation Safety Officer will conduct a clearance survey. Radiation Warning Signs can
only be removed by the Radiation Safety Officer.
Chapter 8 Surveys
The Radiation Safety Officer will make annual independent surveys (audits) of all active radioisotope
laboratories. Surveys of laboratory work surfaces and floors will be performed regularly when the
laboratory is in use. Labs may be audited on a more frequent schedule depending on the amount of
radioactivity in use. Such things as inventory assessment, contamination control, and waste disposal
practices will be addressed during these audits.
Survey (audit) results will be forwarded to the authorized user, and a recheck may be conducted in the
event problems have been detected that need corrective action.
8.1 Operating Procedures to Be Utilized by RSO
The following areas will be swipe tested and surveyed at the intervals indicated:
1. Areas in which radioactive wastes are stored at least monthly
2. Areas in which sealed sources are stored or used: every 6 months
3. Areas authorized for use with radioactive materials in which no radioactive materials have
been used or stored during the previous month will not be swipe tested or surveyed until
actual use has resumed.
Areas in which less than 1 mCi of radioisotopes of low energy (<0.3 MeV) have been used will not
require survey with a hand held survey meter.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 23
Swipes will each cover a 100 cm² area. Each swipe will be counted by liquid scintillation counting or
other instrument in a low background area.
8.2 User Guidelines for Conducting Surveys
1. Surveys will be conducted each day that loose or uncontained radioactive material is used. Use
areas will be swipe tested and surveyed with a survey meter (if appropriate for the radioisotope)
after use for the purpose of detecting contamination. Areas in which only small quantities of
radioactive material (less than 200 uCi) are used will be surveyed weekly, rather than daily.
Swipe tests will be done after a known or suspected spill of radioactive material. Areas where
the contamination level exceeds 200 dpm/ 100 cm2
or is found to be twice background will be
decontaminated and retested.
2. Swipes will each cover a 100 cm² area. Each swipe will be counted by liquid scintillation counting
or other instrument in a low background area.
3. Prior to disposing of radioactive material, a survey will be performed of all material that will be
disposed to ensure that radiation levels are at or below background. Measurement will be
performed with an appropriate instrument. All records of disposal will be kept until the ADH
terminates the license.
4. Records of all surveys must be maintained for a minimum of 3 years after the record is made, for
review in accordance with RH-1500 of the ADH Rules and Regulations. The minimum
information will include:
a. Location, date and identification of equipment used, including the serial number,
calibration date and pertinent counting efficiencies.
b. Name of person conducting the survey.
c. Drawing of area surveyed, identifying relevant features such as active storage areas,
active waste areas, etc.
d. Measured exposure rates, keyed to location on the drawing (point out rates that require
corrective action).
e. Detected contamination levels, keyed to locations on drawing.
f. Corrective action taken in the case of contamination (as defined above) or excessive
exposure rates (exposures likely to exceed 10% of the exposure limits defined in RH1200 of the ADH Rules and Regulations); reduced contamination levels or exposure
rates after corrective action and any appropriate comments.
8.3 Contamination Levels
Removable surface contamination levels shall be controlled such that a level of 200 dpm per 100 cm2
is
not exceeded. When removable radioactivity is found above the set limit, the area must be
decontaminated and then re-surveyed and documented. Nonremovable contamination should be
labeled and shielded whenever possible in order to maintain ALARA limits.
It is understood, that certain areas may be routinely contaminated, such as internal parts of equipment
and inside areas of glassware, and that it may not be practical to decontaminate these surfaces after
each use. The equipment should be monitored routinely and cleaned periodically. Signs must be posted
and protective clothing and gloves should be used when in contact with these areas.
Radioactive contamination levels of air and water in restricted areas must be controlled such that the
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 24
levels specified in RH 2200 Appendix A, Table I, of the ADH Rules and Regulations are not exceeded. In
unrestricted areas, contamination levels of air and water shall not exceed those specified in RH 2200,
Appendix A, Table II.
8.4 Leak Tests
A sealed source is radioactive material that is permanently bonded or fixed in a capsule or matrix
designed to prevent release and dispersal of the radioactive material under the most severe conditions
which are likely to be encountered in normal use and handling (RH-200.av).
Each sealed source containing radioactive material shall be tested for leakage and/or contamination in
accordance with the requirements of RH-1212 of the ASBH Rules and Regulations for Control of Sources
of Ionizing Radiation at intervals not to exceed six months. In the absence of a certificate from a
transferor, indicating that a test has been made within six months prior to the transfer, the sealed
source shall not be put into use until tested. Leak tests will be performed on sealed sources if they
appear to be damaged.
If the test reveals the presence of 0.005 microcuries or more of removable contamination, the licensee
shall immediately withdraw the sealed source from use and and shall cause it to be decontaminated and
repaired or to be disposed of in accordance with Department regulations. A report shall be filed within
5 days of the test with the Radiation Controls Section Arkansas Department of Health, Radiation Control,
4815 West Markham, Slot 30, Little Rock, AR 72205, describing the equipment involved, the test results,
and the corrective action taken.
Tests for leakage and/or contamination shall be performed by the Radiation Safety Officer or Assistant
Radiation Safety Officer, analysis of the leak test shall be performed by persons specifically authorized
by the Department, the U.S. Nuclear Regulatory Commission, or an Agreement State to perform such
services. All leak tests will adhere to manufacturer instructions for that specific unit. Kits for and the
testing of sealed sources at A-STATE are from National Leak Testing Center, Troxler Electronic
Laboratories, Inc. and Integrated Environmental Management, Inc.
The periodic leak test required by this condition does not apply to sealed sources that are stored and
not being used. The sources excepted from this test shall be tested for leakage prior to use or transfer
to another person unless they have been leak tested within six months prior to the date of use or
transfer.
8.4 Survey Instruments and Calibration
To facilitate safe practice in the University, the Radiation Safety Committee requires that an appropriate
calibrated survey meter be available to users. The calibration procedures will be conducted by the RSO
in accordance to the Arkansas State University license.
Instruments must be calibrated at least annually and after servicing. Calibrations will be performed by
Ludlum Measurements, Inc., or another approved reference laboratory utilizing radionuclide sources.
Calibration will be performed at two points on each scale used for radiation protection purposes. The
two points will be approximately 1/3 and 2/3 of full scale. A survey instrument may be considered
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 25
properly calibrated when the instrument readings are within ± 10 percent of the calculated or known
values for each point checked. Readings within ± 20 percent are considered acceptable if a calibration
chart, graph or response factor is prepared, attached to the instrument and used to interpret readings
to within ± 10 percent. Also, when higher scales are not checked or calibrated, an appropriate
precautionary note will be posted on the instrument. Survey instruments will be calibrated by the
manufacturer. The Radiation Safety Officer must be informed prior to the purchase of a new instrument
or repair and factory calibration of an existing instrument.
Upon receipt of the calibrated survey meter, the RSO will verify detection limits by the use of a check
source (Dosimeter Model 3060 Dosimeter Calibrator; Cs-137). A reference check will be performed by
the RSO for each survey meter on a quarterly basis.
Calibration of the Beckman Coulter Scintillation Counter (Model LS6500 in ABI 356) will be conducted
annually by a service representative of Beckman Coulter, in accordance with manufacturer instructions.
If the instrument contains an internal radioactive standard, the Radiation Safety Officer must be notified
prior to disposal of the instrument, so that proper inventory and disposition can be assured.
Chapter 9 Radioactive Waste
All radioactive waste must be disposed of in accordance with State Rules and Regulations. Ultimate
disposal of wastes must be carried out by the Radiation Safety Officer. Sealed sources will be returned
to the manufacturer for disposal. Complete records of all waste disposals must be maintained. Detailed
regulations for waste disposal are found in sections RH-1400 through RH-1407 of the ADH Rules and
Regulations.
9.1 Decay in Storage
Waste containing radioisotopes with short half-lives (e.g., P-32) may be stored in an approved area until
the radioactivity has decayed to background levels for sewer discharge. Any waste that will decay in
storage will be stored in LSE 102E until six half-lives of the radioactive isotope has passed. All wastes
must be clearly labeled as radioactive with the radioisotope indicated and the date that it is placed in
storage. After the amount of residual radioactivity has been determined to be at background levels
(confirmed by scintillation) and this information recorded, the radiation safety officer may dispose of the
material.
9.2 Disposal of Liquid Waste
The ADH Rules and Regulations for disposal of liquid wastes are such that this is the least expensive and
most preferred method of radioactive waste disposal. The regulation that limits release of radioactive
materials into uncontrolled areas is RH-1402; actual limits for disposal of radioactive wastes to the
sewer system are found in RH-1402. In calculating whether disposal of radioactivity in this manner is
permitted, please note that the volume of water leaving the A-State campus in a month is approximately
38,000,000 liters. The radioactivity in liquid wastes must be readily soluble (or readily dispersible
biological material) in water. Radioactive material can only be disposed into the sanitary sewer system
by the Radiation Safety Officer. Radioactivity contained in scintillation vials can be disposed via the
sewer system by the RSO as long as it does not contain ingredients that cause disposal to be in violation
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 26
of EPA or other agency regulations for the control of hazardous chemicals. The committee recommends
the use of so-called biodegradable scintillation fluid for this reason. Scintillation vials that cannot be
disposed in this manner must be accumulated as solid waste and transferred to a licensed radioactive
waste hauler for transport and disposal.
9.3 Disposal of Solid Waste
Radioactive material that cannot be dissolved in water or decayed in storage must be treated as solid
waste. This generally entails transfer of control to a low-level waste processor for disposal. Disposal in
this manner is expensive, and details of the process are found in RH-1402 in the Rules and Regulations.
At the present time, storage of such waste is minimal; due to periodic changes in approved waste
handler, at the time as disposal is warranted an approved waste handler with an Arkansas vendor
license will be identified and contacted for disposal.
9.4 Animal Waste
Arkansas State University is not currently considering conducting research involving radioisotopes with
animals. No protocols will be approved for such research. Regardless of the radioactivity involved, the
user is responsible for complying with all applicable federal, state, and local regulations relating to
disposal of hazardous or toxic materials.
9.5 Records of Disposal
For all radioactive waste that is generated, records shall be maintained where required. The records
shall include the date of disposal and the amount disposed.
Chapter 10 Emergency Procedures
In any radiation emergency, personnel protection and emergency medical care have priority over
radioactive decontamination of the building and equipment. For all cases, contact the Radiation Safety
Officer 870-972-3644 , after hours 864-710-2933 who must be notified as soon as possible.

Arkansas State University must notify the Arkansas Department of Health as soon as possible but not
later than four (4) hours after the discovery of an event that may allow unnecessary exposure to or
release of radiation or licensed radioactive material in excess of regulatory limits. Events may include
fires, natural disasters, explosions or toxic gas releases, etc.
10.1 Accident Procedures
In emergency or accident situations involving radioactive material, the following steps should be taken.
1. Restrict Access: Persons in the immediate area should be asked to leave the area. Establish a
restricted area boundary, limiting access to the area to authorized personnel only.
2. Maintain Surveillance: The restricted area must be kept under constant, direct observation.
3. Portable Gauges: Portable gauge emergency procedures will comply with Appendix X.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 27
4. Notify:
a. The local authorities by dialing 911
b. The Radiation Safety Officer 972-3644 (W) or 864-710-2933 (H) or the Assistant
Radiation Safety Officer 870-972-3086, after hours 870-897-6439. If the incident falls
under the requirements of Paragraphs RH-1501 and/or RH-1502 of the Arkansas Rules
and Regulations for Control of Sources of Ionizing Radiation, the Arkansas Department
of Health must also be notified 1-501-661-2136.
c. In the event of any transportation accident involving radioactive material, both the
Arkansas Department of Health and the Arkansas State Police must be notified.
IMPORTANT: DO NOT HANDLE UNATTACHED OR UNSHIELDED SOURCES OF RADIOACTIVE MATERIAL.
Decontamination and recovery operations should only be attempted by properly trained individuals,
under the direct supervision of the Radiation Safety Officer and using proper handling tools.
Chapter 11 Administrative Procedures
The Committee, the Radiation Safety Officer, or the University Safety Officer can initiate investigations
of safety violations. The Committee may request the Radiation Safety Officer to make special
investigations of any facilities where radiation sources are used.
11.1 Violation Procedures
Upon investigation, should the Radiation Safety Officer find any violations, the following guidelines will
be utilized:
1. All emergencies that create a situation that is immediately dangerous to the life and health
(IDLH) of any person must be corrected immediately or shutdown of the space will occur.
2. Verbal warning to user, outlining deficiencies found and how these deficiencies should be
corrected.
3. Follow-up investigation to be conducted within 30 days of verbal warning. Failure to correct
prior violations will result in a written warning, requiring the Principal User to provide a written
response as to how the deficiencies have been corrected. A copy of this investigation will be
sent to the Associate Vice Chancellor of Research as well as the department head and/or dean
to whom the person in violation of the rules reports.
4. A follow-up investigation will be conducted within 30 days of the second audit. Failure to meet
conditions one and two which are previously listed will result in loss of user privileges.
The Radiation Safety Committee or the Radiation Safety Officer reserve the right to revoke the user’s
authorization, at any time, if in the Committee’s opinion or the Radiation Safety Officers opinion, the
health or safety of persons or property are placed in immediate danger. If any violation of university
safety rules leads to and radiation exposure, radiation level or concentration of radioactive materials
that exceeds the limits mandated by the Arkansas Department of Health, the event will be reported to
the state in accordance with RH-1504. All decisions regarding the cessation of radioactive materials use
by university personnel are communicated to the Associate Vice Chancellor of Research. Any violation
that directly affects other radiation users will be communicated to them via email; if a violation affects a
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 28
space used by multiple users, access to the space will be controlled by the radiation safety officer until
such time as the violation is corrected.
11.2 Recordkeeping
All records regarding radiation safety are kept by the radiation safety officer in binders corresponding to
the year in which the records are created. The only exception to this is the personnel dosimetry records.
Since there is sensitive information on these records, the personnel dosimetry records are kept in a
locked cabinet under the control of the radiation safety officer.
Appendix I Radiation Safety Committee Membership
Dr. Bruce Johnson, Ph.D., Chair, Radiation Safety Committee, (Professor of Physics)
(bjohnson44@gmail.com)
Melissa Dooley, M.S., EHS Director (mdooley@astate.edu)
Ben Rougeau, DVM, Assistant RSO, Chemistry & Physics (brougeau@astate.edu)
David Gilmore, Ph.D., Biological Sciences (dgilmore@astate.edu)
Cheryl DuBose, Ed.D., RT(R)(MR)(CT)(QM), Health Professions (cdubose@astate.edu)
Ronald Johnson, Ph.D. Biological Sciences (rlj@astate.edu)
Appendix II Acceptable Training and Experience Requirements for Users of Radiation
Sources
II.1 Principal User
This individual is expected to be faculty wishing to utilize radioisotopes in teaching or research. To be
approved as a principal user, an individual must demonstrate previous experience, successfully
complete the Arkansas Department of Health (ADH) training disc or complete another approved course.
Demonstration of previous experience can consist of a training certificate from another institution, first
authorship on a paper in which radioisotopic use was a major component of the research methods, or a
passing score on the exam at the end of the ADH training disc. Individuals without previous experience
must successfully complete the ADH training disc or an approved alternative course. Training will
include the following subject areas:
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 29
1. Radiation terminology
2. Basic radiation physics
3. Biological effects of radiation
4. Radiation instruments
5. Radiation in everyday life
6. Regulations and responsibilities
7. Standard safety procedures
8. Emergency procedures
Annual refresher training is also required. Annual refresher training may be postponed if no radioactive
materials have been used in the previous year until the next use of radioactive materials.
II.2 Authorized User
This individual is expected to be a student or staff member working with radioisotopes under the
authority of a Principal user. To become an Authorized user, an individual must successfully complete
the ADH training disc or an alternative approved course, and be approved by the Radiation Safety
Committee. An Authorized user may work with radioactive material without direct supervision and may
be designated to supervise an individual user.
Annual refresher training is also required. Annual refresher training may be postponed if no radioactive
materials have been used in the previous year until the next use of radioactive materials.
II.3 Individual User
This individual is expected to be a student working with radioactivity under the direct supervision of a
Principal or designated Authorized user. Direct supervision means that a supervisor is present and
attentive to the activities of the individual user. Allowing an Individual user to work unsupervised is a
violation of the license and could result in the termination of the project. An Individual user must
receive adequate training from the RSO, the USO, or the principal user, and this training will be
documented by an exam given by the RSO covering most of the same topics listed above but in lesser
depth. Informal instruction by the Principal user and completion of the ADH training disk or an
alternative approved course prior to handling radioisotopes will also be considered for approval by the
Radiation Safety Committee.
II.4 Ancillary Personnel
These are individuals with access to controlled areas (faculty, students, and staff such as housekeeping)
that do not work with radioactive materials. All individuals with such access will receive simple,
documented training on the basics of radiation safety from the RSO. Any individuals who do not agree to
be trained or violate regulations will have their access to these areas revoked. This training occurs on an
annual basis.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 30
Appendix III Inventory and Disposal Log for Radioactive Material
Sample
Inventory
Date
received or
used
Isotope Form Amount
before use
Amount
after use User PO
Activity
before
use
Activity
after use
10/23/2006 C-14 Butyric Acid 2.5 mL 2.5 mL John Doe DO2314 250 uCi 250 uCi
12/25/2006 C-14 Butyric Acid 2.5 mL 2.25 mL Joe Smith 250 uCi 225 uCi
01/12/2007 C-14 Butyric Acid 2.25 mL 1.85 mL Dawn
Brown 225 uCi 185 uCi

For Items not used monthly, an
amount must be entered into the
balance column for the month.



Disposal
Log

Date Isotope Form Amount
added
Total
amount
User Activity
added
Total
activity
12/30/2006 C-14 Butyric Acid 0.25 mL 0.25 mL Joe Smith 25 uCi 25 uCi
01/25/2007 C-14 Butyric Acid 0.40 mL 0.65 mL Dawn
Brown 40 uCi 65 uCi
Use separate container for Separate
isotopes

Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 31
Appendix IV Request for Approval to Use and Acquire Radioactive Material
REQUEST FOR APPROVAL TO USE and ACQUIRE RADIOACTIVE MATERIAL
Date:______________________ Principal User:___________________________
Department:________________ Campus Phone: ________Email:______________
Radioisotope (type, maximum amount and chemical form)
____________________________________________________________________________________
1. On an attached sheet, describe how and where the radioisotope will be used. Include an outline
of the research protocol in sufficient detail for the Committee to review. Include the equipment
which may be used, handling procedures, the types of waste that will be generated, and how
the waste will be disposed in accordance with state and federal regulations and A-STATE policy.
Include a list of expected authorized and individual users whom you expect to be working on
this project.
2. Your signature below indicates that you have read, understood, and agreed to the following:
□ I will comply with all policies, rules, and regulations as outlined in the A-STATE Radiation
Safety Manual, the A-STATE Radioactive Materials License, and the "Rules and Regulations
for Control of Sources of Ionizing Radiation" of the state of Arkansas.
□ I assume all the responsibilities of Principal user as outlined in the A-State Radiation Safety
Manual.
□ I will maintain all necessary records to document use and disposal of radioactive materials.
□ All radioactive materials sent or brought to campus must be shipped directly to the RSO and
not to Central Receiving to check for contamination and for addition to the inventory.
□ The RSO will inspect and swipe test my facility monthly.
□ I and my project are responsible for the cost of all cleanup/disposal/testing
required/recommended by the RSO or by state or federal authorities.
_______________________________ ___________ ___________
Signature Date
Transmit original and 6 copies to A-STATE Radiation Safety Committee, c/o Melissa Dooley, RSO, P.O.
Box 1530, Environmental Health and Safety (ext. 2862).
RSC use only: Approved Tabled for clarification Rejected
Conditionally approved if: _______________________________________________________________
____________________________________ _________________________
RSO Signature Date
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 32
REQUEST FOR ACQUISITION OF RADIOACTIVE MATERIAL
Date:______________________ Principal User: _______________________________
Department:_________________ Campus Phone: __________Email:_________________
Radioisotope (type, max. amount, and chemical form): ______________________________
Vendor/Catalog # of radioisotope _____________________________________________
Expected Period of Use: ____________________________________________________
Who are the expected authorized and individual users whom you expect to be working with this
reagent? _________________________________________________________________
Your signature below indicates that you have read, understood, and agreed to the following:
□ I will comply with all policies, rules, and regulations as outlined in the A-STATE Radiation Safety
Manual, the A-STATE Radioactive Materials License, and the "Rules and Regulations for Control
of Sources of Ionizing Radiation" of the state of Arkansas.
□ I assume all the responsibilities of Principal user as outlined in the A-STATE Radiation Safety
Manual.
□ I will maintain all necessary records to document use, and disposal of radioactive materials.
□ All radioactive materials sent or brought to campus must be shipped directly to the RSO and not
to Central Receiving to check for contamination and for addition to the inventory.
□ The RSO will inspect and swipe test my facility monthly.
□ I and my project are responsible for the cost of all cleanup/disposal/testing
required/recommended by the RSO or by state or federal authorities.
____________________________________________ _ __________________
Principle User Signature Date
_____________________________________________ ____________________
RSO Signature Date
BILLING INFORMATION:
Please bill this radioisotope order to the following:
GRANT # COST ALLOCATION (%) GRANT PI(s)

FORWARD INVOICE FOR PAYMENT OF BILL TO:
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 33
Appendix V Logbook for Radioactive Material
Each Principal user must maintain a logbook in the laboratory that contains records of radioisotope use,
and disposal. The log book must be separate of other lab notebooks and readily accessible to the RSO or
other inspectors.
Contents:
1) Log of Radioactive Materials on Hand: Every time radioactive material is received, the following
information must be entered into the log: Isotope, chemical form, amount (Ci or mCi), volume,
and date of arrival. Each entry must be on a separate page with ample room after the entry to
record changes in amounts during usage. Every time radioactive material is used, the following
information must be entered into the log: date of use, the volume (or mass) of material used,
the volume (or mass) disposed, and the volume (or mass) remaining. At least once a week, the
remaining balance of radioactivity must be entered; decay of short half-life radioisotopes must
be taken into account.
2) Log of Swipe Tests: Swipe tests must be performed at least weekly when using 200uCi or less.
Workers using in excess of 200 uCi in a day must perform swipe tests daily at the conclusion of
the experiment. The logbook should contain a map of the laboratory with radioactive use areas
clearly indicated.
Numbered swipe tests should be keyed to the map and the areas briefly described. It is highly
recommended that the same core swipe areas be numbered the same from week to week. Core
areas should include the work area, around the work area, any sink for radioactive disposal, and
high traffic areas that may have been contaminated (floor near door, doorknobs, telephone).
Additional locations should include any place a spill may have occurred (bench, floor) or places
that have been handled (lid of microcentrifuge, controls for gel dryer). Background (paper disk
in scintillation fluor) should be determined each time; you may use the same background vial
over and over. Vials that register background levels can be utilized for repeated swipe tests.
Swipe tests twice background must be redone following decontamination of the affected area.
Swipe test data must be dated and legibly entered into the log. Scintillation counter printouts
may be saved as additional documentation.
Sample Log
S-35
Date Task Volume Used/DIsposed Balance Volume Balance Activity
4/26/17 Receipt of S-35 Methionine 0.5 mL 0.5 mL 0.5 mCi
4/28/17 Used to label cultures 0.1 mL (all sink) 0.4 mL 0.4 mCi
4/30/17 Used to label cultures 0.1 mL (all sink) 0.3 mL 0.3 mCi
5/3/17 Inventory 0 0.3 mL 0.28 mCi
5/10/17 Inventory 0 0.3 mL 0.27 mCi
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 34
Appendix VI ADH Form Y
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 35
Appendix VII Notice to Employees
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 36
Appendix VIII Materials Licensed for Use at Arkansas State University
Appendix IX Guidelines for Bioassays
IX.1 Conditions under Which Bioassays May Be Necessary for the Use of I-125 and I-131
1. When an individual handles in open form unsealed quantities of radioactive iodine that exceed
those shown in Table 1 below. The quantities shown in Table 1 apply to both the quantity handled
at any one time or integrated as the total amount of activity introduced into a process by an
employee over any 3-month period.
2. When quantities handled in unsealed form are greater than 10% of Table 1 values, routine bioassay
may still be necessary under certain circumstances. A written justification for not performing such
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 37
measurements should be prepared and recorded whenever bioassay is not performed and the
quantities handled exceed 10% of the levels in Table 1.
3. Bioassay is generally not required when process quantities handled by a worker are less than 10%
of those in Table 1.
Types of bioassays that should be performed are:
1. Baseline: Prior to beginning work with radioactive iodine in sufficient quantity that bioassay is
specified in Item 1 above.
2. Routine: At the frequency specified.
3. Emergency: As soon as possible after any incident that might cause thyroid uptakes to exceed
burdens given below, so that recommended actions can be most effective.
Show in the application that the need for bioassays has been thoroughly considered and that the
proposed bioassay program is appropriate for the intended use of radioactive material.
Submit procedures for bioassays that address at least the following:
1. Frequency of testing.
2. Methods used for testing (e.g., thyroid scan, urinalysis), including a description of the
procedures involved.
3. Determination of baseline values on individuals involved.
4. Instrumentation used.
5. Provisions for monitoring excretion of radioactive material in any individual who shows
radionuclide uptake.
6. Action levels for the tests and the corrective action to be taken when these levels are exceeded.
Recommended action levels for thyroid burden at the time of measurement is 0.12 microcurie
of I-125 and 0.04 microcurie of I-131.
NOTE: Guidance on bioassay program for I-125 and I-131 is provided in NRC Regulatory Guide 8.20. If
bioassays are not considered appropriate for the proposed program, specify the reasons for this
conclusion.


Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 38
TABLE 1
ACTIVITY LEVELS ABOVE WHICH BIOASSAY FOR I-125 OR I-131 IS NECESSARY
ACTIVITY HANDLED IN UNSEALED FORM
MAKING BIOASSAY NECESSARY

TYPES OF OPERATION VOLATILE OR DISPERSIBLE BOUND TO NONVOLATILE
AGENT
Processes in open room or
bench, with possible escape of
iodine from process vessels.
1 mCi 10 mCi
Processes with possible
escape of iodine carried out
within a fume hood of
adequate design, face
velocity, and performance
reliability
10 mCi 100 mCi
Processes carried out within
glove boxes, ordinarily closed,
but with possible release of
iodine from process and
occasional exposure to
contaminated box and box
leakage.
100 mCi 1000 mCi
IX.2 Additional Information for Use of Tritium (H-3)
IX.2.1 Special Surveys
IX.2.1.1 Airborne Tritium
If Tritium is requested in sufficient quantity and form as to be airborne, air monitoring for Tritium may
be necessary. Describe the procedures and equipment used to perform this monitoring, including
appropriate action levels. Specific regulatory requirements for airborne radioactive material
concentrations in restricted areas are contained in Paragraph RH-1201 of the Arkansas Board of Health’s
Rules and Regulations for Control of Sources of Ionizing Radiation.
IX.2.1.2 Contamination Surveys
Since Tritium tends to be a persistent and pervasive contamination problem, a rigorous program for
conducting wipe surveys (smears) of Tritium use and storage areas should be implemented. Wipes
should be taken of any surface that may have been contaminated on at least a weekly basis. Action
levels for these surveys should be no higher than 200 dpm/100 cm. Describe the procedures and
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 39
equipment involved in performing wipe surveys of Tritium use and storage area, including frequency,
action levels, materials involved and the person responsible for conducting surveys.
IX.2.2 Handling of Contaminated Material
Some materials, which may become contaminated by Tritium during routine operations, include soil,
building materials and transformer and lubricating oils in particle accelerators with Tritium targets.
Describe the procedures used to decontaminate and/or dispose of material that has been
contaminated. Also, describe the control procedures that will be implemented to reduce the possibility
of Tritium contamination.
IX.2.3 Bioassay Methods
Bioassays may be required for persons working with millicuries (or higher) quantities of Tritium. Submit
procedures for Tritium bioassay, which address at least the following:
1. Frequency of testing.
2. Method of testing (e.g., urinalysis) including a description of the specific procedures involved.
3. Determination of baseline values on individuals involved.
4. Instrumentation used.
5. Action levels for bioassays.
6. Corrective actions to be taken when action levels are exceeded, including provisions for
monitoring excretion of Tritium or for retesting of individuals which show uptake.
7. A bioassay should be performed within one month of the last possible exposure to Tritium,
when operations are being discontinued, or when the worker is terminating activities with
potential exposure.
Routine bioassay is necessary when quantities processed by an individual at any one time or the total
amount processed per month exceed those for the forms of Tritium shown in Table 2. Under certain
circumstances, routine bioassay may still be necessary when quantities are less than the levels in Table 2
but more than 10% of those levels. A written justification for not performing bioassays should be
presented in these cases.
Special bioassay measurements may be needed to verify the effectiveness of respiratory protective
devices or protective clothing used to prevent inhalation or absorption of Tritium. These special
bioassays should be performed to determine the actual Tritium intake of an individual wearing a
respiratory protective device or protective clothing if the concentration of Tritium (in any form) in the
air is such that exposure for 40 hours per week for 12 weeks to the uniform concentration of Tritium in
air specified in Table 1, Column 1, of Paragraph RH-2200, Appendix A. Special bioassay procedures
should also be conducted for personnel wearing respirators if, for any reason, the average Tritium
concentration in air and the duration of exposure are unknown or can not be conservatively estimated
by calculation.
Bioassays should be performed when air monitoring indicates exposures may exceed 25% of the
quarterly limit on intake (inhalation plus absorption) in Paragraph RH-1201 (a)(1). This 25% value should
be taken to be 1.6 millicuries. *
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 40

Multiplying the concentration given in RH-2200, 5x10-6 Ci/ml, by 6.3x108
ml gives the corresponding
quarterly intake of Tritium by inhalation. In the case of inhaled HTO, which mixes instantly with other
water molecules after entering body fluids, the intake may be assumed equal to the uptake. The uptake
of Tritium (as HTO) by absorption through the skin is assumed equal to the uptake by inhalation unless
the form of Tritium in the air can be demonstrated to have lower uptakes. The total uptake, including
skin absorption, would be assumed to be about 6.3 mCi, which delivers a dose commitment of about
1.25 rems to standard man (using Q = 1.7). A 40-hour occupational exposure at a concentration of 5x10-
6 Ci/ml would thus result in an intake of 6.3/13=0.48 mCi and a dose commitment of about 0.1 rem.
An acute intake (in less than one day) of 0.48 mCi would result in an initial body water concentration of
about 11 Ci/liter.
IX.2.4 Bioassay Frequency Guidelines
IX.2.4.1 Initial Routine
A bioassay sample of at least 100 ml of urine should be taken within 72 hours following entry of an
individual into an area where operations require bioassay according to the criteria in this guide and then
every two weeks or more frequently thereafter as long as the individual is working with Tritium. When
work with Tritium is on an infrequent basis (less frequently than every two weeks), bioassay should be
performed within 10 days of the end of the work period during which Tritium was handled.
IX.2.4.2 After Three Months
A sampling frequency selected in accordance with the above paragraph may be changed to quarterly if,
after three months, the following three conditions are met:
1. The average urinary Tritium concentration from specimens obtained during the 3-month period
does not exceed 3 Ci/L,
2. If measurements of the concentration of Tritium in air are required as a condition of the license,
the quarterly average concentration (Ci/ml) to which the workers are exposed multiplied by
the factor 6.3 x 108 ml does not exceed 0.8 mCi and
3. The working conditions during the 3 month period, with respect to the potential for Tritium
exposure, are representative of working conditions during the period in which a quarterly
urinalysis frequency is employed, and there is no reasonable expectation that the criteria given
in items a and b above will be exceeded.
IX.2.4.3 After Use of Respiratory Protective Devices or Protective Suits
A bioassay sample should be taken within 72 hours after respiratory protective devices; suits, hoods or
gloves are used to limit exposure as stated in this guide.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 41
IX.2.5 Bioassay Action Level and Corresponding Action Guidelines
IX.2.5.1 Biweekly or More Frequent Sampling
Whenever the intake of Tritium within any 40-hour work period exceeds the amount that would be
taken into the body from uniform exposure for 40 hours at the air concentration (5 x 10-6 Ci/ml)
specified in Table 1, Column 1 of Appendix A, paragraph RH-2200, the licensee is required to make
evaluations, take necessary corrective actions and maintain records by Paragraph RH-1201 (b) (2).
If urinary excretion rates exceed 5 Ci/L but are less than 50 Ci/L, the following course of action should
be taken:
1. A survey of the operations involved, including air and surface contamination monitoring, should
be carried out to determine the causes of the exposure and evaluate the potential for further
larger exposures or for the possible involvement of other employees.
2. Any reasonable corrective actions that the survey indicates may lower the potential for further
exposures should be implemented.
3. A repeat urine sample should be taken within one week of the previous sample and should be
evaluated within a week after collection. Internal dose commitments should be estimated using
at least these two urine sample evaluations and other survey data, including the probable times
of the intake of Tritium.
4. Any evidence indicating that further work in the area might result in an employee receiving a
dose commitment in excess of the limits established in RH-1200 should serve as cause to
remove the employee from work in the operation until the source of exposure is discovered and
corrected.
5. Reports or notification must be provided as required by RH-1504 and RH-2804, or as required by
conditions of the license pursuant to RH-1205.
If urinary excretion rates exceed 50 Ci/L, the following course of action should be taken:
1. Carry out all steps in Item above.
2. If the projected dose commitment exceeds levels for whole body as provided in RH-1502,
provide appropriate notification to the Department.
3. Refer the case to appropriate medical/health physics consultations for recommendations
regarding immediate therapeutic procedures that may be carried out to accelerate removal of
Tritium from the body and reduce the dose to as low as is reasonably achievable.
4. Carry out repeated sampling (urine collections of at least 100 ml each) at approximately oneweek intervals at least until samples show an exception rate less than 5 Ci/L. If there is a
possibility of long-term organic compartments of Tritium that require evaluation, continue
sampling as long as necessary to ensure that appreciable exposures to these other
compartments do not go undetected and to provide estimates of total dose commitments.
IX.2.5.2 Quarterly Sampling
Carry out the actions called for when any of the levels indicated in the above paragraphs are exceeded.
In addition, reinstitute biweekly (or more frequent) sampling for at least the next 6-month period, even
when urinary excretion falls below 5 Ci/L.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 42
Appendix X Operating, Transport, Security and Emergency Guidelines for Portable Gauges
X.1 Operating Procedures
The following Operating Procedures will be used by all Authorized Users to remove, transport, use and
return the gauge to storage. Any deviations from these Operating Procedures must be approved by the
Radiation Safety Officer. Only individuals that have been taken the training provided by Troxler on the
use of the portable gauge may use the gauge. The certificate must be provided to the RSO prior to the
gauge being used.
X.1.1 Preparation for Work
1. In regards to personnel monitoring:
a. Always wear your assigned badge when using the gauge.
b. Never wear another person's badge.
c. Never store your badge near the gauge.
2. Before removing the gauge from its place of storage, ensure that, where applicable, each gauge
source is in the fully shielded position and that in gauges with a movable rod containing a sealed
source, the source rod is locked (e.g., keyed lock, padlock, mechanical control) in the shielded
position. Place the gauge in the transport case and lock the case.
3. Sign out the gauge in a Utilization Log book (that remains at the storage location) including the
date(s) of use, name(s) of the authorized users who will be responsible for the gauge, and the
temporary jobsite(s) where the gauge will be used.
4. Block and brace the gauge to prevent movement during transport and lock the gauge in or to
the vehicle. Follow all applicable Department of Transportation (DOT) requirements when
transporting the gauge.
X.1.2 Using the Gauge
1. Use the gauge according to the manufacturer's instructions and recommendations and the
Operating Procedures and Emergency Procedures. The gauge will also be used in a manner that
will keep radiation doses As Low As is Reasonably Achievable (ALARA) by:
a. Minimize the TIME spent in close proximity to the gauge (the shorter the time, the
lower the dose);
b. Maximize the DISTANCE from the gauge (doubling the distance reduces radiation
intensity); and
c. Make use of available SHIELDING to block out radiation.
2. Establish and maintain constant surveillance of the restricted area and always keep
unauthorized persons away from the gauge.
3. Do not touch the unshielded source rod with your fingers, hands, or any part of your body.
4. Do not place hands, fingers, feet, or other body parts in the radiation field from an unshielded
source.
5. Unless absolutely necessary, do not look under the gauge when the source rod is being lowered
into the ground. If you must look under the gauge to align the source rod with the hole, follow
the manufacturer's procedures to minimize radiation exposure.
6. After completing each measurement in which the source is unshielded, immediately return the
source to the shielded position.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 43
7. Always maintain constant surveillance and immediate control of the gauge when it is not in
storage. At job sites, do not walk away from the gauge when it is left on the ground. Take
actions necessary to protect the gauge and yourself from danger of moving heavy equipment.
8. Always keep unauthorized persons away from the gauge.
9. Perform routine cleaning and maintenance according to the manufacturer's instructions and
recommendations.
10. When the gauge is not in use at a temporary jobsite, place the gauge in a secured storage
location (e.g., locked in the trunk of a car or locked in a storage shed).
11. Do not smoke, eat, drink, or store any of these types of products in the use or storage area of
the gauges containing radioactive material.
X.1.3 Completing the Work
1. Prior to transporting the gauge, ensure that, where applicable, each gauge source is in the fully
shielded position. Ensure that in gauges with a movable source rod, the source rod is locked in
the shielded position (e.g., keyed lock, padlock, mechanical control). Place the gauge in the
transport case and lock the case. Block and brace the case to prevent movement during
transportation. Lock the case in or to the vehicle.
2. Return the gauge to its proper locked storage location at the end of the work shift.
3. Log the gauge into the Utilization Log when it is returned to storage.
4. After making changes affecting the gauge storage area (e.g., changing the location of gauges
within the storage area, removing shielding, adding gauges, changing the occupancy of adjacent
areas, moving the storage area to a new location), reevaluate compliance with public dose limits
and ensure proper security of gauges.
X.1.4 Maintaining the Gauge
1. Personnel monitoring badges will always be worn when performing non-routine maintenance
on the gauge.
2. Routine cleaning and maintenance of the gauge will be performed in accordance with the
manufacturer’s instructions and recommendations.
3. No maintenance will be performed on the gauge that includes removing the radioactive source
from the gauge. Any maintenance that is not included in the manufacturer’s instructions and
recommendations will be performed by the manufacturer or by another person who is
specifically licensed to perform the maintenance.
4. A Quarterly Inventory of all gauges will be performed by the Radiation Safety Officer or their
designee. Records of the inventory shall be maintained on file for inspection purposes and shall
be retained for at least 3 years following the date the record was created. 5. Leak testing of the
radioactive sources will be performed and documented every six months in accordance with the
Radioactive Material License. Gauges that do not have a current leak test will not be used.
X.2 Transportation of Portable Gauges
U.S. DOT requirements for highway shipments via common carrier are similar to requirements for
transporting a gauge to a temporary job site. Operators are responsible for ensuring that their gauges
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 44
are properly packaged, marked, labeled, secured, blocked and braced, and that proper documentation
accompanies the devices.
The following discussion serves as basic guidance only. The U.S. DOT regulations should be consulted
prior to packaging and transporting radioactive material.
X.2.1 Marking
Markings and labels on gauge transport containers must be durable, legible, in English, and printed on or
affixed to the package surface (e.g., a label, tag or sign).
Required markings include:
1. Shipping name (ex.: radioactive material, special form, n.o.s., Class 7)
2. RQ (for gauges with an Am-241:Be source > 10 mCi); add to shipping name)
3. Identification number (ex.: UN 3332)
4. Package type (ex.: TYPE A)
X.2.2 Labeling
Required labels include:
1. “Cargo Aircraft Only” label (required for shipments by air)
2. Two DOT warning labels (gauges typically require RADIOACTIVE YELLOW II labels; see table)
applied to opposite sides of the package, listing the package contents and activity in SI and
customary units, and the package’s Transport Index (TI), the dimensionless number indicating
the package’s radiation level at 1 meter (manufacturers provide the TI for their gauges).
Packaging Labeling Criteria
Warning Label Max. Rad. Level at Package
Surface (mR/hr)
Max. Rad. Level at 1 m (TI)
Radioactive White I 0.5 None
Radioactive Yellow II 50 1
Radioactive Yellow III 200 10
X.2.3 Shipping Papers
The information required on shipping papers depends on the type of shipment being made.
Transporting gauges to and from temporary job sites in company vehicles (without any transfers) can be
exclusive use shipments, which require minimal information on the shipping paper (commonly known as
a “bill of lading”). Gauges shipped by common carrier to the manufacturer or another recipient require
additional information. Gauges shipped by air or internationally require still more information.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 45
1. Exclusive use shipments (shipments to and from job sites) require a bill of lading with the
information listed below. The shipping paper must be immediately accessible to the driver
during transport.
a. Description of shipment [proper shipping name, RQ (if applicable), identification
number, hazard class, type of package, name and activity of each nuclide, category of
labeling and Transport Index)
b. Emergency response telephone number (24-hour monitored number of a person
knowledgeable about the hazards associated with portable gauges)
2. Common carrier shipments (shipments offered to third parties for transport) require a bill of
lading with the information listed below, if the shipment is made by highway. If shipped by air,
the carrier will provide a “Dangerous Goods Airbill” that will describe the required information:
a. Name and address of shipper [can be the consignee (company offering the package for
shipment) or the consignor (company shipping the package)]
b. Description of shipment (same as for exclusive use shipments)
c. Emergency response telephone number (24-hour monitored number of a person
knowledgeable about the hazards associated with portable gauges)
d. Shipper’s certification (statement certifying that the package has been properly
classified, described, packaged, marked and labeled, and is in proper condition for
transportation)
e. Signature of shipper (commits the signor to certification of the shipment)
3. Emergency response information (ERI) will be provided with the bill of lading and will be
immediately accessible to the driver during shipment.
4. Accessibility: Shipping papers and ERI will be immediately accessible to the driver during
transport of gauges.
X.2.4 Inspection
Prior to shipment, inspect transport containers to ensure proper packaging and unimpaired physical
condition of the container and its closure devices. Promptly report any defects to the RSO prior to
shipment or use. The RSO will label and remove from use any gauge or package found to be defective
and ensure their repair or replacement.
X.2.5 Blocking and Bracing
Block and brace gauge transport containers to prevent shifting during normal transportation conditions.
Gauges cannot be transported in a vehicle’s passenger compartment.
X.2.5 Expected Instruments/Articles
Portable devices classified as excepted instruments/articles (e.g., XRF analyzers) are exempt from
marking, labeling and shipping paper requirements, but must have a notice included with the package
that lists the company’s name and provides the following statement: “This package conforms to the
conditions and limitations specified in 49 CFR 173.424 for radioactive material, excepted package--
instruments or articles, UN2910.”
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 46
X.3 Security of Portable Gauges
X.3.1 Storage and Control of Licensed Radioactive Materials
The Rules and Regulations for Control of Sources of Ionizing Radiation, Paragraph RH-1306, “Storage of
Sources of Radiation” requires licensees to secure sources of radiation from unauthorized removal or
access. Further, Paragraph RH-1308, “Control of Material Not in Storage” states that the licensee shall
control and maintain constant surveillance of radioactive material that is in a controlled or unrestricted
area and that is not in storage.
Despite these requirements, thefts of portable gauges do occur which can pose a potential risk to public
health and safety.
X.3.2 Security Requirements
The Department is providing licensing guidance to applicants to assist them in improving their gauge
security program. Improved security programs for portable gauges that comply with the provisions of
this Appendix will be required in order to obtain or renew an Arkansas Radioactive Material License. This
Appendix requires individuals using portable gauges under specific licenses to use a minimum of two
independent physical controls that form tangible barriers to secure portable gauges from unauthorized
removal, whenever portable gauges are not under the control and constant surveillance of the licensee.
The proposed physical controls may also reduce accidental losses such as gauges falling out of a vehicle
while in transit.

This Appendix applies to a licensee with a portable gauge regardless of the location, situation, and
activities involving the portable gauge. At all times, the licensee would be required to either maintain
control and constant surveillance of the portable gauge or use a minimum of two independent physical
controls to secure the portable gauge. The Department expects that the physical controls would be
designed and constructed of material suitable for securing the gauges from unauthorized removal and
that the physical controls could not be easily defeated by the use of small hand tools. In addition, the
Department expects that both of the controls must be defeated for the portable gauge to be removed
to deter a theft by requiring a more determined effort to remove the gauge.
X.3.3 Securing a Portable Gauge at a Licensed Facility
Long term storage of portable gauges is usually at a permanent facility listed in the license or license
application. When a portable gauge is stored at a licensed facility, the licensee is required to use a
minimum of two independent physical controls to secure the gauge. Examples of two independent
physical controls to secure a portable gauge when stored at a licensed facility are as follows:
1. The portable gauge or transportation case containing the portable gauge is stored inside a
locked storage shed within a secured outdoor area, such as a fenced parking area with a locked
gate.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 47
2. The portable gauge or transportation case containing the portable gauge is stored in a room
with a locked door within a secured building for which the licensee controls access by lock and
key or by a security guard.
3. The portable gauge or transportation case containing the portable gauge is stored inside a
locked, non-portable cabinet inside a room with a locked door if the building is not secured.
4. The portable gauge or transportation case containing the portable gauge is stored in a separate
secured area inside a secured mini-warehouse or storage facility.
5. The portable gauge or transportation case containing the portable gauge is physically secured to
the inside structure of a secured mini-warehouse or storage facility.
X.3.4 Securing the Portable Gauge in a Vehicle
Licensees commonly use a chain and a padlock to secure a portable gauge in its transportation case to
the open bed of a pickup truck while using the vehicle for storage. Because the transportation case is
portable, a theft could occur if the chain is cut and the transportation case with the portable gauge in it
is taken. If the licensee simply loops the chain through the handles of the transportation case, a thief
could open the transportation case and take the portable gauge without removing the chain or the case.
Because the transportation case is also portable, it must be protected by two independent physical
controls if the portable gauge is inside. A lock on the transportation case or a lock on the portable gauge
source rod handle would not be sufficient because the case and the gauge are portable.
A vehicle should be used for storage only for a short period of time when a gauge is in transit. Portable
gauges should only be kept in a vehicle overnight if it is not practicable to provide temporary storage in
a permanent structure. When a portable gauge is being stored in a vehicle, the licensee would be
specifically required to use a minimum of two independent physical controls to secure the gauge.
Examples of two such independent physical controls to secure portable gauges in these situations are:
1. The locked transportation case containing the portable gauge is physically secured to a vehicle
with brackets, and a chain or steel cable (attached to the vehicle) is wrapped around the
transportation case such that the case cannot be opened unless the chain or cable is removed.
In this example, the transportation case would count as one control since the brackets would
prevent easy removal of the case. The chain or cable looped only through the transportation
case-handle is not acceptable.
2. The portable gauge or transportation case containing the portable gauge is stored in a box
physically attached to a vehicle, and the box is secured with (1) two independent locks, or (2)
two separate chains or steel cables attached independently to the vehicle in such a manner that
the box cannot be opened without the removal of the chains or cables, or (3) one lock and one
chain or steel cable is attached to the vehicle in such a manner that the box cannot be opened
without the removal of the chain or cable.
3. The portable gauge or transportation case containing the portable gauge is stored in a locked
trunk, camper shell, van, or other similar enclosure and is physically secured to the vehicle by a
chain or steel cable in such a manner that one would not be able to open the case or remove
the portable gauge without removal of the chain or cable. In this example, the transportation
case would not count as one control because it could be easily removed.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 48
X.3.5 Securing a Portable Gauge at a Temporary Job Site or at Locations other than a
Licensed Facility
When a job requires storage of a portable gauge at temporary job sites or at locations other than a
licensed facility, the licensee must use a permanent structure for storage if practicable to do so. Storage
of radioactive material in a private residence or motel/hotel room overnight on a temporary basis is not
authorized or approved. When a portable gauge is stored at a temporary job site or at locations other
than an authorized facility, the licensee is required to use a minimum of two independent physical
controls to secure the gauge. Examples of two independent physical controls to secure portable gauges
at such locations are:
1. At a temporary job site, the portable gauge or transportation case containing the portable gauge
is stored in a locked non-portable structure (e.g., construction trailer, sea container, etc.), and is
physically secured by a chain or steel cable to the structure in such a manner that an individual
would not be able to open the transportation case or remove the portable gauge without
removing the chain or cable. A lock on the transportation case or a lock on the portable gauge
source rod handle would not be sufficient because the case and the gauge are portable.
2. The portable gauge or transportation case containing the portable gauge is stored inside a
locked room within a temporary facility, and is physically secured by a chain or steel cable to a
permanent or non-portable structure (e.g., large metal drain pipe, support column, etc.) such
that an individual would not be able to open the transportation case or remove the portable
gauge without removing the chain or cable.
3. The portable gauge or transportation case containing the portable gauge is stored in a locked
garage, and is within a locked vehicle or is physically secured by a chain or steel cable to the
vehicle in such a manner that an individual would not be able to open the transportation case or
remove the portable gauge without removing the chain or cable.
4. The portable gauge or transportation case containing the portable gauge is stored in a locked
garage, and is within a locked enclosure or is physically secured by a chain or steel cable to a
permanent or non-portable structure in such a manner that an individual would not be able to
open the transportation case or remove the portable gauge without removing the chain or
cable.
X.3.6 Controlling and Maintaining Constant Surveillance of a Portable Gauge
When a portable gauge is not secured with a minimum of two independent physical controls, the
licensee is required to control and maintain constant surveillance of the gauge. This is consistent with
Paragraph RH-1308, which states that the licensee shall control and maintain constant surveillance of
licensed material that is in a controlled or unrestricted area and that is not in storage. Control and
constant surveillance is required when the gauge is not in storage, e.g., is in use or undergoing
maintenance. The Department interprets “control and maintain constant surveillance” of portable
gauges to mean being immediately present or remaining in close proximity to the portable gauge so as
to be able to prevent unauthorized removal of the gauge.
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 49
X.4 Emergency Procedures for Portable Gauges
If the source fails to return to the shielded position (e.g., as a result of being damaged, source becomes
stuck below the surface) or if any other emergency or unusual situation arises (e.g., the gauge is struck
by a moving vehicle, is dropped, or is in a transport vehicle involved in an accident) specific response
actions must be taken.
X.4.1 Individual at the Scene
The individual at the Scene must do the following:
1. RESTRICT ACCESS: Immediately secure the area and establish a restricted area boundary. Keep
individuals at least 15 feet away from the gauge until the situation is assessed and radiation
levels are known. However, perform first aid for any injured individuals and remove them from
the area only when medically safe to do so.
2. MAINTAIN SURVEILLANCE: Maintain constant, direct surveillance of the restricted area by an
Authorized User.
3. DETAIN INDIVIDUALS: If any heavy equipment is involved, detain the equipment and operator
until it is determined there is no contamination present.
4. REMAIN AT THE SCENE: Gauge users and other potentially contaminated individuals should not
leave the scene except for immediate medical attention.
5. NOTIFY: Notify the persons in the order listed below of the situation:
NAME WORK PHONE NUMBER HOME PHONE NUMBER
Melissa Dooley, RSO 870-972-3644 870-761-0377
Ben Rougeau 870-972-3086 870-897-6439
6. FOLLOW DIRECTIONS: Follow the directions provided by the person contacted above.
X.4.2 RSO and License Management
The RSO and License Management must do the following:
1. Arrange for a radiation survey to be conducted as soon as possible by a knowledgeable person
using appropriate radiation detection instrumentation. This person could be a licensee
employee using a survey meter located at the job site or a consultant. To accurately assess the
radiation danger, it is essential that the person performing the survey be competent in the use
of the survey meter.
NOTE: DO NOT HANDLE UNSHIELDED SOURCES OF RADIOACTIVE MATERIAL
Arkansas State University Environmental Health
and Safety Radiation Safety Manual | 50
2. If gauges are used for measurements with the unshielded source extended more than 3 feet
below the surface, contact persons listed on the emergency procedures need to know the steps
to be followed to retrieve a stuck source and to convey those steps to the staff on site.
3. Make necessary notifications to local authorities as well as the Arkansas Department of Health,
1-800-633-1735 or 1-501-661-2136 (staffed 24 hours a day) Immediate Department notification
is required when gauges containing radioactive material are lost or stolen, when gauges are
damaged or involved in incidents, and when it becomes apparent that attempts to recover a
source stuck below the surface will not be successful.
4. Reports to the Department must be made within the reporting timeframes specified by the
regulations.
5. Reporting requirements are found in Paragraphs RH-1501 and RH-1502.
6. Recovery operations and decontamination must only be attempted by properly trained and
licensed individuals.
Note: In the event of a transportation accident involving radioactive material, the
Arkansas Department of Health, the Arkansas State Police and the U.S. Department
of Transportation must be notified.